My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
1963 ORD NO 1146
Colton
>
CITY CLERK
>
City Council Ordinances
>
1900s
>
1963 (1146 - 1174)
>
1963 ORD NO 1146
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2014 3:35:29 AM
Creation date
2/20/2014 1:34:08 PM
Metadata
Fields
Template:
General Documents
Created By
cityclerk
DocType
General Documents
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1� <br />2 <br />3 <br />i <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />ll <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />24 <br />25 <br />26 <br />27 <br />28 <br />29 <br />30 <br />31 <br />32 <br />Iwill interfere with any service entrance equipment. Service not in conformity <br />I herewith shall be relocated to suitable locations with the approval of both the <br />I serving utility and the Electrical Safety Engineer. <br />Section 150. 31. Methods for underground services. <br />Galvanized Rigid Conduit <br />I Shearduct Rigid Conduit <br />PQ V. C. Heavy Wall <br />Transite Type (2) <br />Transite Type (1) <br />Fiberduct <br />Tileduct <br />Aluminum Rigid Conduit <br />Direct <br />Burial <br />Concrete <br />Encased <br />Section 150. 32. No swimming pool shall be constructed directly beneath <br />an existing service drop, unless the service entrance conduit and service <br />entrance conductors can be extended or relocated to a location where the service <br />drop will not be above the pool area. The point of attachment of the service <br />drop shall have the approval of both the serving utility and the Electrical Safety <br />Engineer. <br />Section 150. 33. (1) Where more than one re -inspection of each phase of <br />work is required to show compliance with these codes by reason of defective <br />material or workmanship, or inadequate or improper installation, a fee may be <br />charged for each subsequent inspection. Such fee shall be Three Dollars <br />($3. 00) per hour with a minimum. charge of three dollars ($3. 00). <br />(2) Inspection fees not specified herein shall be charged for at the rate <br />of Three Dollars ($3. 00) per hour with a minimum charge of Three Dollars <br />($3. 00). <br />SECTION FIVE: The following sections are deleted from said Uniform <br />Wiring Code, 70. 3, 70. 4, 110. 4, 150. 12 through 150. 27, 170.5. <br />The following is added to Section 170.17; all wiring to detached garages <br />or accessory buildings shall be underground in rigid raceway or other approved <br />method. Exception. Overhead wiring a minimum of twelve feet (121.) high may <br />1 be used when the horizontal run exceeds one hundred feet (loot). <br />2 SECTION SIX: The word City in the aforesaid sections and Code shall be <br />
The URL can be used to link to this page
Your browser does not support the video tag.