My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
O-006-13 2013 California Building Code
Colton
>
CITY CLERK
>
City Council Ordinances
>
2000s
>
2011-2021
>
2013
>
O-006-13 2013 California Building Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/11/2020 4:54:33 PM
Creation date
11/11/2020 4:54:03 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />24 <br />25 <br />26 <br />27 <br />28 <br />3. SECTION 903.2.1.1 Group A-1 is hereby amended to read as follows: <br />903.2.1.1 Group A-1. An automatic sprinkler system shall be provided for Group A-1 <br />occupancies where one of the following conditions exists: <br />1. The fire area meets or exceeds 5,000 square feet; <br />2. The fire area has an occupant load of 300 or more; <br />3. The fire area is located on a floor other than the level of exit discharge; or <br />4. The fire area contains a multi -theater complex. <br />4. SECTION 903.2.1.2 Group A-2 is hereby amended to read as follows: <br />Section 903.2.1.2 Group A-2. An automatic sprinkler system shall be provided for <br />Group A-2 occupancies where one of the following conditions exist: <br />1. The fire area meets or exceeds 5,000 square feet; <br />2. The fire area has an occupant load of 100 or more; or <br />3. The fire area is located on a floor other than the level of exit discharge. <br />5. SECTION 903.2.1.3 Group A-3 is hereby amended to read as follows: <br />903.2.1.3 Group A-3. An automatic sprinkler system shall be provided for Group A-3 <br />occupancies where one of the following conditions exist: <br />1. The fire area meets or exceeds 5,000 square feet; <br />2. The fire area has an occupant load of 300 or more; or <br />3. The fire area is located on a floor other than the level of exit discharge. <br />6. SECTION 903.2.1.4 amended is hereby amended to read as follows: <br />903.2.1.4 Group A-4. An automatic sprinkler system shall be provided for Group A-4 <br />occupancies where one of the following conditions exist: <br />1. The fire area meets or exceeds 5,000 square feet; <br />2. The fire area has an occupant load of 300 or more; or <br />3. The fire area is located on a floor other than the level of exit discharge. <br />7. SECTION 903.2.2.1 Group B is hereby added to read as follows: <br />903.2.2.1 Group B. An automatic sprinkler system shall be provided for all buildings <br />containing a Group B occupancy with a fire area of 5,000 square feet or greater. <br />8. SECTION 903.2.3 Group E is hereby amended to read as follows: <br />903.2.3 Group E. An automatic sprinkler system shall be provided for Group E <br />occupancies as follows: <br />1. Throughout all Group E fire areas 5,000 square feet or greater in area. <br />9. SECTION 903.2.4 Group F-1 is hereby amended to read as follows: <br />903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all <br />23152.06300\8351650.2 - 6 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.